首页 | 本学科首页   官方微博 | 高级检索  
     

高压加热器疏水管道振动原因分析
引用本文:赖汉贤. 高压加热器疏水管道振动原因分析[J]. 水利电力机械, 2009, 0(5): 11-12
作者姓名:赖汉贤
作者单位:广东粤泷发电有限责任公司,广东罗定527217
摘    要:引起设备振动的原因很多,根据#5高压加热器疏水管道振动原因的分析结果,逐项进行了排查和处理,最终找到了引起管道振动的主要原因。采取了有效措施,使高压加热器疏水管道振动的问题得到了明显改善。

关 键 词:高压加热器疏水管道  振动  原因分析  排查  措施

Reason analysis of drain pipe vibration of high pressure heater
LAI Han-xian. Reason analysis of drain pipe vibration of high pressure heater[J]. Water Conservancy & Electric Power Machinery, 2009, 0(5): 11-12
Authors:LAI Han-xian
Affiliation:LAI Han-xian (Guangdong Yuelong Power Generation Corporation Limited, Luoding 527217, China)
Abstract:There are many reasons which can cause equipment vibration. According to the reason analysis of drain pipe vibration of high pressure heater No. 5, the possible reasons were checked and processed one by one, and the main reason causing pipe vibration was found finally. The effective measures were adopted, and the vibration of drain pipe of high pressure heater was weakened obviously.
Keywords:drain pipe of high pressure heater  vibration  reason analysis  check  measure
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号