首页 | 本学科首页   官方微博 | 高级检索  
     


A new calibration facility for water flowrate at high Reynolds number
Authors:Noriyuki Furuichi  Hiroshi Sato  Yoshiya Terao  Masaki Takamoto
Affiliation:1. Fluid Flow Division, National Metrology Institute of Japan, AIST, Tsukuba Central 3, 1-1-1, Umezono, Tsukuba, 305-8563, Japan;2. Metrology Management Center, National Metrology Institute of Japan, AIST, Tsukuba Central 3, 1-1-1, Umezono, Tsukuba, 305-8563, Japan
Abstract:A new test facility has been constructed for the National Metrology Institute of Japan (NMIJ) and the National Institute of Advanced Industrial Science and Technology (AIST) for calibration of feedwater flowmeters used in nuclear power stations at Reynolds numbers of up to 18 million. This very large Reynolds number is achieved in a 600 mm pipe at a flowrate of 3.33  m3/s (12,000  m3/h) and a water temperature of 70  °C. This calibration facility consists of a circulation loop with four pumps and four reference flowmeter sets, a prover system, a heating and cooling unit, and other components. The expanded uncertainty of this facility is 0.077%. The present paper describes, in detail, the new facility, the calibration method of the reference flowmeter, experiments for flow field, uncertainty estimation, and the results of an example calibration.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号