阳泉市某八层住宅楼纠偏工程实例
引用本文:张仁,朱进军,田庆路,王海洋,马博恒. 阳泉市某八层住宅楼纠偏工程实例[J]. 勘察科学技术, 2000, 0(5): 28-32
作者姓名:张仁  朱进军  田庆路  王海洋  马博恒
作者单位:1. 阳泉煤业集团有限责任公司,山西,阳泉,045000
2. 冶金工业部勘察研究总院,河北,保定,071069
摘    要:阳泉市洪城河 1 3号居民住宅楼近东西走向 ,因地基不均匀沉降 ,整体向南倾斜 ,倾斜率达 1 2 %。基于对地基土、基础和上部结构特征的分析 ,采用了楼房北侧基础下水平孔掏土纠偏 ,南侧灌注桩加固的综合治理方法 ,纠偏治理效果极其理想。

关 键 词:住宅  纠偏  加固
修稿时间:2000-01-25

AN ENGINEERING CASE OF THE TILTING RECTIFICATION OF A 8-STOREY RESIDENCE BUILDING IN YANGQUAN CITY
Zhang Ren,Zhu Jinjun,Tian Qinglu,Wang Haiyang,Ma Boheng. AN ENGINEERING CASE OF THE TILTING RECTIFICATION OF A 8-STOREY RESIDENCE BUILDING IN YANGQUAN CITY[J]. Site Investigation Science and Technology, 2000, 0(5): 28-32
Authors:Zhang Ren  Zhu Jinjun  Tian Qinglu  Wang Haiyang  Ma Boheng
Abstract:The Hongchenghe No 13 residential building of Yangquan city is oriented near the direction of east-west Because of the non-uniform settlement of the foundation, it is tilted as a whole to the south side with a rate reaching 1 2%. Based on the analysis of the ground soil, foundation and the characteristics of the superstructure, the following synthetic treatment method has been adopted: at the north side of the building, the tilting is rectified by extracting the soils using horizontal holes digged under the foundations; at the south side, the foundations are strengthened by using cast-in-place piles As a final result of this treatment, it is proved to be very ideal
Keywords:residential building  tilting rectification  strengthening