首页 | 本学科首页   官方微博 | 高级检索  
     


Performance evaluation of a.c. and d.c. direct coupled photovoltaic water pumping systems
Authors:Meirios Moechtar   Melanie Juwono  Eddy Kantosa
Affiliation:

Directorate for Conversion and Conservation of Energy, BPP Teknologi, Jl. M. H. Thamrin 8, Lt. 14, Jakarta 10340, Indonesia

Abstract:Photovoltaic (PV) water pumping systems have been widely tested and assessed in Indonesia because of the deficiency of potable water in remote areas. Several different PV water pumping systems, such as a.c./d.c. with/without battery and various pumps, have been tested in the field. Further study, evaluation and classification of optimized PV water pumping systems is needed. Three of those pumping systems were installed in Sumba Island in 1983, in three adjacent villages with similar climate and environment conditions. Two of the installations had a.c. direct coupled systems and the other had d.c. The a.c. systems used a 3.65 kWp PV generator each and the d.c. system used 5.76 kWp. After comparing the performance data of both systems, it can be concluded that the a.c. system performs better and needs less maintenance on the pump. In May 1987, as a result of this evaluation, the 5.76 kWp d.c. system was replaced by an a.c. one, and its capacity was increased to 9.22 kWp. Meanwhile, the 3.65 kWp a.c. system was increased to 3.88 kWp.
Keywords:Photovoltaic   Direct coupled   Pumping systems
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏