首页 | 本学科首页   官方微博 | 高级检索  
     


Experimental assessment of hygrothermal performance of an interior thermal insulation system using a laboratory technique simulating on-site conditions
Authors:Zby&scaron  ek Pavlí  k,Robert Černý  
Affiliation:Department of Building Materials, Faculty of Civil Engineering, Czech Technical University in Prague, Thákurova 7, 166 29 Prague 6, Czech Republic
Abstract:A laboratory technique simulating on-site conditions is used for hygrothermal performance assessment of two building envelopes. Interior thermal insulation system on the basis of hydrophilic mineral wool which is applied on two common load bearing structures is analyzed. Sufficiently large specimens of studied building envelopes are exposed to difference climate conditions very close to reality. Monitoring of moisture and temperature fields in the investigated structures is carried out using laboratory measuring technology. Experimental results give evidence that the hygrothermal performance of both tested building envelopes is satisfactory.
Keywords:Interior thermal insulation system   Hydrophilic mineral wool   Brick   Argillite   Hygrothermal performance   Experimental assessment
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏