首页 | 本学科首页   官方微博 | 高级检索  
     


Determination of ambient and personal dose equivalent for personnel and cargo security screening
Authors:Hupe O  Ankerhold U
Affiliation:Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany. oliver.hupe@ptb.de
Abstract:In the past few years, imaging technology using ionising radiation has been gaining in importance for the screening of goods and persons for security reasons and in order to detect contraband. For radiation protection purposes it is extremely important to know that dose persons are exposed to when passing through a personnel scanner or, as a stowaway, in a cargo scanner, so as to remain within the prescribed dose limits. Within the scope of a research project, measurements were performed on different types of personnel X-ray scanners as well as cargo X-ray scanners, using the transmission and/or the backscattering method. All scanners investigated operate with a high dose rate and use short irradiation time. Owing to this method of scanning reliable values can only be determined for the personal and ambient dose equivalents, H(p)(10) and H(*)(10), by using a specially developed measuring system. The aim of this project was to determine the range of magnitudes of doses for representative personnel and cargo X-ray scanner systems. Depending on the type of scanner, the determined dose values for personnel scanners range from 0.07 microSv to 6 microSv. Measurements and instruments used in this study are described and the dose values obtained are discussed in detail.
Keywords:
本文献已被 PubMed Oxford 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号