首页 | 本学科首页   官方微博 | 高级检索  
     

近红外光谱采集方式与样品形态对带鱼新鲜度检测结果的影响
引用本文:孟一, 张玉华, 许丽丹, 陈东杰, 张咏梅, 张应龙. 近红外光谱采集方式与样品形态对带鱼新鲜度检测结果的影响[J]. 食品工业科技, 2014, (11): 282-287. DOI: 10.13386/j.issn1002-0306.2014.11.053
作者姓名:孟一  张玉华  许丽丹  陈东杰  张咏梅  张应龙
作者单位:山东商业职业技术学院山东省农产品贮运保鲜技术重点实验室;国家农产品现代物流工程技术研究中心
基金项目:国家科技支撑计划(2013BAD19B02);山东省优秀中青年科学家科研奖励基金(BS2011NY020)
摘    要:研究了近红外漫反射和漫透射两种方式以及鱼糜和整鱼两种形态对带鱼新鲜度检测结果的影响。利用积分球漫反射系统采集400010000cm-1范围内的带鱼鱼糜漫反射、漫透射和整鱼漫反射光谱,根据训练集交叉验证均方差(RMSECV)及相关系数r对建模参数进行优化,分别建立了挥发性盐基氮(TVBN)、pH和菌落总数的偏最小二乘(PLS)定量检测模型。根据模型对预测集样品的预测均方差(RMSEP)及其相关系数r以及配对t-检验验证模型的预测能力。结果表明,所建模型对带鱼新鲜度的预测性能均良好。但近红外漫反射与漫透射两种光谱采集方式相比,前者所建模型的预测能力高于后者。采用漫反射光谱时,鱼糜模型的预测能力高于整鱼。因此,检测带鱼新鲜度时宜采用鱼糜的漫反射光谱。 

关 键 词:近红外漫反射光谱  近红外漫透射光谱  TVBN  pH  菌落总数  PLS
收稿时间:2013-10-15

Effect of different near infrared spectroscopy ( NIR) acquisition ways and sample states on the ribbonfish freshness detection results
MENG Yi, ZHANG Yu-hua, XU Li-dan, CHEN Dong-jie, ZHANG Yong-mei, ZHANG Ying-long. Effect of different near infrared spectroscopy ( NIR) acquisition ways and sample states on the ribbonfish freshness detection results[J]. Science and Technology of Food Industry, 2014, (11): 282-287. DOI: 10.13386/j.issn1002-0306.2014.11.053
Authors:MENG Yi  ZHANG Yu-hua  XU Li-dan  CHEN Dong-jie  ZHANG Yong-mei  ZHANG Ying-long
Affiliation:1.Shandong Institute of Commerce and Technology, Shandong Key Laboratory of Storage and Transportation Technology of Agricultural Products;2.National Engineering Research Center for Agricultural Products Logistics
Abstract:The effect on the ribbonfish freshness detection results was studied using diffuse reflection and diffuse transmission of NIR, and minced and complete ribbonfish.The diffuse reflection and diffuse transmission spectrum of minced ribbonfish and the diffuse reflection spectrum of complete ribbonfish were collected respectively using integrating sphere diffuse system in the range of 4000 ~ 10000cm- 1.The model parameters were optimized according to the cross- validation mean square error ( RMSECV) of training set and the correlation coefficient r.Quantitative detection models of total volatile basic nitrogen ( TVBN) , pH and total number of colonies were established respectively by partial least squares ( PLS) .Predictive ability of the models were verified by prediction mean square error ( RMSEP) , correlation coefficient r and paired t- test.Results showed that prediction performance of the models for the determination of the freshness of ribbonfish was good.But near infrared diffuse reflection compared with diffuse transmission, the prediction ability of the former was higher than the latter.The model's prediction ability of minced ribbonfish was higher than that of the complete ribbonfish when using diffuse reflection spectrum.Therefore, diffuse reflection spectrum of minced ribbonfish was appropriate when testing ribbonfish freshness.
Keywords:near infrared diffuse reflection spectrum  near infrared diffuse transmission spectrum  TVBN  pH  total number of colonies  PLS
本文献已被 CNKI 等数据库收录!
点击此处可从《食品工业科技》浏览原始摘要信息
点击此处可从《食品工业科技》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号