Experimental Observation on the Effectiveness of Fiber Sheet Strip Stirrups in Concrete Beams |
| |
Authors: | Chadon Lee Jun-Yeop Kim Seo-Young Heo |
| |
Affiliation: | 1Professor, School of Architecture and Building Science, College of Engineering, Chung-Ang Univ., Seoul 156-756, Korea. (corresponding author) E-mail: cdlee@cau.ac.kr 2Graduate student, Graduate School of Architectural Engineering, Chung-Ang Univ., Seoul 156-756, Korea.
|
| |
Abstract: | Experimental observations were made for the effectiveness of fiber sheet strips (FSSs) as internal stirrups in comparison with fiber-reinforced polymer (FRP) rod stirrups and steel stirrups. A total number of 10 concrete beams were tested under three-point loading. Each beam measured 1,400 mm long, 150 mm wide, and 250 mm deep. Their shear span-depth ratios were 2.5. The beams were composed of different shear reinforcements: one without stirrups, two with steel stirrups, one with carbon FRP rod stirrups, and the rest with different types of FSS stirrups. The main variables include stirrup types, strengthening of bent portions of FSS stirrups, impregnation, and shear reinforcement ratio for FSS stirrups. Test results indicated that concrete beams reinforced with FSS stirrups had enhanced shear strength over the beam without shear reinforcements. Moreover, the FSS stirrup-reinforced beams could maintain comparable shear behavior to that of the concrete beam reinforced with steel stirrups in overall load-deflection relationships, shear strengths, crack patterns, and crack widths at maximum load. |
| |
Keywords: | Fiber reinforced polymers Concrete beams Shear tests Shear strength Failure modes |
|
|