摘    要:随着C网运营承接,如何在确保C网安全运行的前提下,稳妥推进基站节能技术应用,是当前面临的新问题。文中通过对3G基站空调的配置要求及使用现状的介绍,阐述了基站一体化空调的工作原理和特点,提出了基站节能、防盗的解决方案,论证了一体化空调在基站使用的实用性。

关 键 词:节能  一体化空调  舒适性空调

The Application of Integrated Air-Conditioning in the 3G Base Station
WU Jian.The Application of Integrated Air-Conditioning in the 3G Base Station[J].Telecom Power Technologies,2012,29(4):110-112.
Authors:WU Jian
Affiliation:WU Jian (Quanzhou Branch of China Telecom, Quanzhou 362000, China )
Abstract:With the undertaking of C network operation, it is the current new problems how to steadily push forward the base station energy-saving technology under the premise of ensuring the safe operation of the C network. Through the introduction of configuration requirements for 3G base stations air-conditioning, the working principle and characteristics of the base station integrated air-conditioning are described; the base station energy saving and anti-theft solutions are put forward; the practicality of using the integration of air conditioning in the base station is demonstrated.