Effect of local background luminance on discomfort glare
Authors:Wonwoo Kim  Yasuko Koga
Affiliation:

Department of Architecture, Human-Environment Studies, Kyushu University, Fukuoka 812-8581, Japan

Abstract:The objective of this research is to propose a practical method of determining the background luminance in the evaluation of discomfort glare. Two experiments were conducted, a visual sensitivity test and a glare sensitivity test. The results show that the luminance of threshold and the luminance of discomfort glare are mainly determined by the luminance of the immediate background of the source, rather than by the average background luminance, which has previously been suggested by unified glare rating and visual comfort probability method. Consequently, when the background contains areas of differing luminance, the background luminance of a glare source should be determined by the local background luminance affecting the local adaptation.
Keywords:Discomfort glare   Background luminance   Local adaptation   Local background
本文献已被 ScienceDirect 等数据库收录!