首页 | 本学科首页   官方微博 | 高级检索  
     


Effects of spray axis incident angle on heat transfer performance of rhombus-pitch shell-and-tube interior spray evaporator
Authors:Ru-Li Lin  Tong-Bou Chang  Chih-Chang Liang
Affiliation:1.Department of Mechanical Engineering,Southern Taiwan University,Tainan,Taiwan
Abstract:An interior spray method is proposed for enhancing the heat transfer performance of a compact rhombus-pitch shell-and-tube spray evaporator. The experimental results show that the shell-side heat transfer coefficient obtained using the proposed spray method is significantly higher than that achieved in a conventional flooded-type evaporator. Four different spray axis incident angles (0°, 45°, 60° and 75°) are tested in order to investigate the effect of the spray inclination angle on the heat transfer performance of the spray evaporator system. It is shown that the optimal heat transfer performance is obtained using a spray axis incident angle of 60°.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏