摘    要:通过对江油发电厂31号、32号锅炉引风机在运行过程中叶片磨损的分析,认为实际燃用原煤比设计燃煤灰份高,叶片受到飞灰的局部磨损和冲蚀,除尘效率降低等是主要原因。后采取加装防磨包板、现场超音速电弧防磨喷涂、耐磨堆焊等防磨措施,取得了较好的效果。

关 键 词:锅炉  离心式引风机  叶片  磨损  防磨技术
文章编号:1671-0320(2002)01-0031-04
修稿时间:2001年5月11日

cause and countermeasures of centrifugal induced draft fan vane abrasion
Long Zhong.cause and countermeasures of centrifugal induced draft fan vane abrasion[J].Shanxi Electric Power,2002(1):31-34.
Authors:Long Zhong
Abstract:In this paper,according to practical experience of recent years,causes of abrasion problems which emerged while the running induced draft fan of 300MW unit 1004 t/h boiler's in Jiangyou Power Plant,are analyzed in detail with preventive measures given,with reliability and economics of boiler operation greatly improved,thus achieving good economic and social benefits.