首页 | 本学科首页   官方微博 | 高级检索  
     


Tensile and impact properties changes of HASTELLOY X after exposure in high-temperature helium environment
Authors:Yasuo Kondo  Kiyoshi Fukaya  Kazuhiko Kunitomi  Yoshiaki Miyamoto
Affiliation:(1) Department of High Temperature Engineering, Tokai Research Establishment, Japan Atomic Energy Research Institute, Tokai-Mura, Naka-Gun, Ibaraki-Ken, 319-11, Japan
Abstract:Experimental results are presented on the changes in mechanical properties of HASTELLOY X* after being used in the liner tube of HENDEL hot gas duct under high temperature helium gas for about 6000 hours. In both room and elevated-temperature tensile tests, 0.2 pct proof stress and total elongation were significantly decreased after exposure in high temperature helium. Room-temperature impact toughness of the exposed specimens exhibited a much lower absorbed energy (about 5.0 × 106 J/m2) than that of unexposed specimens (about 1.5 × 106 J/m2). The fracture modes of tensile test specimens were more closely correlated with the test temperature than with the long-time exposure; however, long-time exposure is more affected by the tensile strength of HASTELLOY X than the test temperature. Moreover, “downstream effect” for the carbide precipitation reaction occurred in the liner tube of the HENDEL hot gas duct. HASTELLOY is a trademark of Cabot Corporation.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号