摘    要:针对某电厂省煤器爆管事故,从各方面进行了检查、分析,发现由于焊接质量的原因,造成高速流体对受热面管的大面积"吹损",从而造成省煤器的爆管,为解决爆管事故提供了技术分析手段.

关 键 词:省煤器  焊接质量  吹损  爆管

Causes of tube explosion of economizers in power plants
LUO Guo-fang,WANG Hao,LIU Qi.Causes of tube explosion of economizers in power plants[J].East China Electric Power,2009,37(3).
Authors:LUO Guo-fang  WANG Hao  LIU Qi
Affiliation:1.East China Electric Power Test & Research Institute Co.;Ltd.;Shanghai 200437;China;2.Shanghai Shangdian Caojing Power Generation Co.;Shanghai 201507;China
Abstract:The causes of economizer tube explosion in a power plant were analyzed,and the results showed that the main cause was due to bad weld quality which resulted in serious washout on heating surfaces by high-velocity fluid body.