高落差敷设XLPE电缆缆芯滑动受力试验
引用本文:刘焕新,许启发,杨洪亮,胡宾,李仁友,聶力军.高落差敷设XLPE电缆缆芯滑动受力试验[J].电线电缆,2006(4):13-15,17.
作者姓名:刘焕新  许启发  杨洪亮  胡宾  李仁友  聶力军
作者单位:山东特变鲁能泰山电缆有限公司,山东,泰安,271200
摘    要:通过对高落差敷设的高压交联聚乙烯(XLPE)绝缘皱纹铝护套电力电缆受力分析,设计了试验方案,对110 kV和220 kV等级的不同截面的电缆进行试验,验证电缆在运行中,缆芯与铝护套之间不存在位移。

关 键 词:高压交联聚乙烯绝缘皱纹铝护套电力电缆  高落差敷设  缆芯滑动  摩擦力  重力
文章编号:1672-6901(2006)04-0013-04
收稿时间:2005-10-25
修稿时间:2005年10月25

Test of the Slippage Forces Acting on the Insulated Conductors in XLPE Cables Installed with high drop
LIU Huan-xin, et al.Test of the Slippage Forces Acting on the Insulated Conductors in XLPE Cables Installed with high drop[J].Wire & Cable,2006(4):13-15,17.
Authors:LIU Huan-xin  
Abstract:The test program was made by analyzing the forces acting on the insulated conductors in HV XLPE insulated corrugated aluminium sheathed power cables installed with high drop.Test was made respectively on 110 kV and 220 kV cables with different sizes.The result shows that during the cable operation,there is no displacement between the insulated conductors and the aluminium sheath.
Keywords:HV XLPE insulated corrugated aluminium sheathed power cable  high-drop installation  slippage of insulated conductors  abrasion force  gravity