首页 | 本学科首页   官方微博 | 高级检索  
     

沧东电厂660MW超临界锅炉结焦特性分析
引用本文:张志远. 沧东电厂660MW超临界锅炉结焦特性分析[J]. 锅炉技术, 2011, 42(1): 60-63
作者姓名:张志远
作者单位:河北国华沧东发电有限责任公司;
摘    要:介绍沧东电厂660 MW超临界锅炉试运期间结焦的情况,分析了结焦的原因,并经投运后的运行实践,提出了防止结焦的相应措施.对同类型锅炉燃烧调整有着一定的参考价值.

关 键 词:超临界锅炉  神华煤  结焦

CangDong Power Plant 660 MW Supercritical Boiler Slagging Analysis
ZHANG Zhi-yuan. CangDong Power Plant 660 MW Supercritical Boiler Slagging Analysis[J]. Boiler Technology, 2011, 42(1): 60-63
Authors:ZHANG Zhi-yuan
Affiliation:ZHANG Zhi-yuanGuohua Cangdong Power Generation Co.Ltd,Cangzhou 061113,China
Abstract:Introduction Cang Dong Power Plant 660 MW supercritical boiler slagging during the trial run the profile,analyze the reasons for slag to settle,and put into operation after operation after practice,and put forward corresponding measures to prevent slagging.Adjusted for the same type of boiler combustion is a certain reference value.
Keywords:supercritical once-through boiler  shenhua coal  slagging  
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号