降温过程中LNG板翅结构应力耦合模拟
引用本文:麻宏强,陈杰,蔡伟华,郑文科,姚杨,姜益强.降温过程中LNG板翅结构应力耦合模拟[J].哈尔滨工业大学学报,2015,47(6):21-26.
作者姓名:麻宏强  陈杰  蔡伟华  郑文科  姚杨  姜益强
作者单位:1. 哈尔滨工业大学 市政环境与工程学院, 150090哈尔滨
2. 中国石油气电集团有限责任公司,100027 北京
3. 哈尔滨工业大学 能源科学与工程学院, 150001哈尔滨
基金项目:国家高技术研究发展计划(863计划)(2013AA09A216).
摘    要:为保证大型LNG冷箱降温过程中板翅式换热器结构安全可靠,建立了板翅结构应力耦合分析模型,采用热-结构直接耦合模拟方法,分析了降温过程对板翅结构应力的影响规律.结果表明:翅片和隔板钎焊接头处为结构最易破坏区;温差对板翅结构应力影响较为明显,并随温差增大而增大;当温差小于10 K时,对流换热性能对板翅结构应力影响较小;当温差相等时,降温速率对板翅结构应力影响较小.

关 键 词:LNG  板翅结构  直接耦合  有限元方法
收稿时间:9/3/2014 12:00:00 AM

Numerical investigation on stress of plate-fin structures during cool-down of LNG heat exchanger
MA Hongqiang,CHEN Jie,CAI Weihu,ZHENG Wenke,YAO Yang and JIANG Yiqiang.Numerical investigation on stress of plate-fin structures during cool-down of LNG heat exchanger[J].Journal of Harbin Institute of Technology,2015,47(6):21-26.
Authors:MA Hongqiang  CHEN Jie  CAI Weihu  ZHENG Wenke  YAO Yang and JIANG Yiqiang
Affiliation:School of Municipal and Environmental Engineering, Harbin Institute of Technology,150090 Harbin, China,CNOOC Gas and Power Group, 100027 Beijing, China,School of Energy Science and Engineering, Harbin Institute of Technology, 150001 Harbin, China,School of Municipal and Environmental Engineering, Harbin Institute of Technology,150090 Harbin, China,School of Municipal and Environmental Engineering, Harbin Institute of Technology,150090 Harbin, China and School of Municipal and Environmental Engineering, Harbin Institute of Technology,150090 Harbin, China
Abstract:In order to ensure the structural safety of plate-fin heat exchanger, a model was proposed to simulate the stress of plate-fin structures in the cool-down process. The stress of plate-fin structures was investigated in the cool-down process based on directly coupled Finite Element Method. The results showed that the most easily damaged area happened in the brazed joint between fin and plate in the cool-down process. At the same time, the stress was obviously influenced by the temperature difference between natural gas (NG) and mixture refrigerant (MR) and increased with increasing temperature difference. The heat transfer performance had little influence on the stress of plate-fin structures when the temperature difference between NG and MR was less than 10 K. The stress of plate-fin structures was also slightly impacted by the temperature drop rate as the temperature drop rate of NG was the same as that of MR in the cool-down process.
Keywords:LNG  plate-fin structures  direct coupling  finite element method