2. 山东省蒙阴建筑设计院,山东,蒙阴,276200
摘    要:论述了电动机几种起动方式的优缺点及适用范围,对两种科技含量较高的软起动器的经济技术指标进行了对比分析,指出在智能大厦及大型民用建筑中的消防工作空调系统等所采用的电动机,其起动装置应采用磁控软起动器。

关 键 词:软起动器  性能  微处理器  电动机
文章编号:1004-289X(2001)06-0016-04

Contrast and Exploration of the Performance of a Soft Starter
CUI Yong - he,YANG Cheng - de.Contrast and Exploration of the Performance of a Soft Starter[J].Electric Switchgear,2001(6):16-19,15.
Authors:CUI Yong - he  YANG Cheng - de
Abstract:The strong and weak points and applicabilty for several kinds of starting ways of a electric motor are expounded in the paper. Two kinds of soft starters which have economic and technical norms with high quality in science and technology are compared and analyzed. It points out electric motors adopted the air - conditioning system of fire engineering in intelligent large building and large - soale civil architecture and magnetic soft staters are adopted for their starting devices.