首页 | 本学科首页   官方微博 | 高级检索  
     

高强冷弯型钢骨架墙体抗剪性能试验研究
引用本文:何保康,郭鹏,王彦敏,周天华,袁耀明. 高强冷弯型钢骨架墙体抗剪性能试验研究[J]. 建筑结构学报, 2008, 29(2): 72-78
作者姓名:何保康  郭鹏  王彦敏  周天华  袁耀明
作者单位:西安建筑科技大学,陕西西安,710055;博思格建筑系统住宅部,上海,201613;长安大学,陕西西安,710061
基金项目:《冷弯薄壁型钢结构技术规范》国家标准管理组专题研究项目
摘    要:对550MPaC型冷弯型钢立柱、550MPa带肋钢板和石膏板组成的高强冷弯型钢骨架墙体进行了16块足尺试件(宽2.4m,高3m)的抗剪试验研究。对带肋钢板+石膏板双面板、单面带肋钢板、单面石膏板和双面无板带交叉扁钢拉条支撑4类墙体试件进行了无竖向力水平单调加载、无竖向力水平低周反复加载和有竖向力水平低周反复加载的试验,得到了各类墙体试件的受剪承载力指标和位移延性系数μ等性能指标。试验结果表明:各类墙体单调加载试件抗剪强度均比反复加载试件高;单面石膏板墙体试件与0.8倍的单面带肋钢板墙体试件的承载力指标之和与双面板墙体试件承载力指标接近;双面无板带交叉扁钢拉条支撑墙体试件抗剪强度是双面板墙体试件的60%~67%;双面板墙体试件延性系数在1.731~2.384之间。

关 键 词:高强冷弯型钢骨架墙体  试验研究  受剪承载力  延性系数
文章编号:1000-6869(2008)02-0072-07
收稿时间:2008-04-05
修稿时间:2007-07-01

Experimental study on shear resistance of high strength cold-formed steel framing walls
HE Baokang,GUO Peng,WANG Yanmin,ZHOU Tianhua,YUAN Yaoming. Experimental study on shear resistance of high strength cold-formed steel framing walls[J]. Journal of Building Structures, 2008, 29(2): 72-78
Authors:HE Baokang  GUO Peng  WANG Yanmin  ZHOU Tianhua  YUAN Yaoming
Affiliation:HE Baokang,GUO Peng,WANG Yanmin,ZHOU Tianhua,YUAN Yaoming (.Xi'an University of Architecture and Technology,Xi'an,China,.Bluescope Steel Building,Shanghai,China,.Changan University,Xi'an,China)
Abstract:The shear resistances of sixteen full-size(2.4m by 3m) specimens of high strength cold-formed steel framing wall were studied in this paper.The walls were made of 550MPa cold-formed steel C-section studs,550MPa cold-formed steel rib panels and gypsum wallboards.Though the test of the four types of walls,double boards,single gypsum wallboard,single steel rib panel and steel X-strap bracing on both sides,under monotonic loading without axial compression loading,cyclic loading without axial compression loading and cyclic loading with axial compression loading,the properties of shear load carrying capacity and the structural ductility factor for the specimens were obtained.Experimental results show that the shear strengths of specimens under monotonic loading are higher than that of specimens under cyclic loading for all types of walls;the sum of the shear resistance of walls with single gypsum wallboard and 0.8 that of walls with single steel rib panel is close to the shear resistance of walls with double boards;the shear strengths of walls with steel X-strap bracing on both sides are 60%-67% that of walls with double boards;the structural ductility factors for the specimens with double boards are between 1.731 and 2.384.
Keywords:high strength cold-formed steel framing wall  experimental study  shear resistance  structural ductility factor
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《建筑结构学报》浏览原始摘要信息
点击此处可从《建筑结构学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏