首页 | 本学科首页   官方微博 | 高级检索  
     

济钢1750m^3高炉风口区冷却壁损坏原因分析及改进
引用本文:高新运,李丙来,杨士岭,郝之峰.济钢1750m^3高炉风口区冷却壁损坏原因分析及改进[J].山东冶金,2009,31(4):23-25.
作者姓名:高新运  李丙来  杨士岭  郝之峰
作者单位:济钢集团有限公司,山东济南,250101
摘    要:针对高炉风口区冷却壁上端容易损坏漏水,影响高炉长寿的问题,分析认为,主要原因是该部位已处于炉腹高温区,铸铁冷却壁不适应高温环境所致。为此,开发应用了一种新型叠合式冷却壁,将风口区铸铁冷却壁上端易损坏部位减薄,在减薄部位叠加一层能够独立冷却的紫铜冷却板,从而增强了炉体耐热性,使风口区冷却壁寿命由1.5a延长到2.25a以上。

关 键 词:高炉  冷却壁  叠合式冷却壁  复合冷却壁  紫铜冷却板

Damage Reason Analysis of the Cooling Stave in Tuyere Region in Jinan Steel's 1750 m~3 BF and Its Improvement
GAO Xin-yun,LI Bing-lai,YANG Shi-ling,HAO Zhi-feng.Damage Reason Analysis of the Cooling Stave in Tuyere Region in Jinan Steel''s 1750 m~3 BF and Its Improvement[J].Shandong Metallurgy,2009,31(4):23-25.
Authors:GAO Xin-yun  LI Bing-lai  YANG Shi-ling  HAO Zhi-feng
Affiliation:Jinan Iron and Steel Group Corporation;Jinan 250101;China
Abstract:According to the fact that the easy damage of upper part of the cooling stave in tuyere region shortens the life of 1 750 m3 blast furnace,it was considered through analysis that,the upper part of the cooling stave in tuyere region was in high temperature zone of bosh,where the cast iron stave can not stand the high temperature,so the damage was induced.Therefore,a new overlapping cooling stave was developped,which made the easy damage part thinner and infront of that overlaps a red copper stave with isolat...
Keywords:blast furnace  cooling stave  overlapping cooling stave  complex plate  red copper cooling plate  