首页 | 本学科首页   官方微博 | 高级检索  
     

DEVELOPMENT OF Sr_(0.69)La_(0.31)F_(2.31)+SrSSOLID ELECTROLYTE SENSOR AND ITS APPLICATION
引用本文:Zhai, Yuchun Ma, Ping Tian, Yanwen Xiao, Fei Ji, Chunlin(Northeastern University,Shonyang 110006). DEVELOPMENT OF Sr_(0.69)La_(0.31)F_(2.31)+SrSSOLID ELECTROLYTE SENSOR AND ITS APPLICATION[J]. 中国有色金属学会会刊, 1995, 0(1)
作者姓名:Zhai   Yuchun Ma   Ping Tian   Yanwen Xiao   Fei Ji   Chunlin(Northeastern University  Shonyang 110006)
作者单位:Northeastern University,Shonyang 110006
摘    要:DEVELOPMENTOFSr_(0.69)La_(0.31)F_(2.31)+SrSSOLIDELECTROLYTESENSORANDITSAPPLICATIONZhai;YuchunMa;PingTian;YanwenXiao;FeiJi;Chun?..


DEVELOPMENT OF Sr_(0.69)La_(0.31)F_(2.31) SrS SOLID ELECTROLYTE SENSOR AND ITS APPLICATION
Zhai, Yuchun Ma, Ping Tian, Yanwen Xiao, Fei Ji, Chunlin. DEVELOPMENT OF Sr_(0.69)La_(0.31)F_(2.31) SrS SOLID ELECTROLYTE SENSOR AND ITS APPLICATION[J]. Transactions of Nonferrous Metals Society of China, 1995, 0(1)
Authors:Zhai   Yuchun Ma   Ping Tian   Yanwen Xiao   Fei Ji   Chunlin
Abstract:A solid electrolyte tube was made with Sr_(0.69)La_(0.31)F_(2.31) SrS co-precipitated powder mixed with 3 wt. -% SrS solid powder. The cell, W|W , WS2|Sr_(0.69)La_(0.31)F_(2.31) SrS |[S]Cu|W , was designed to determine the sulphur activity in liquid copper. The EMF was stable and the cell was reversible. The results of determination conformed with those measured by other authors. The material of Sr_(0.69)La_(0.31)F_(2.31) SrS can be used to make solid electrolyte sensor for sulphur in high temperature melts.
Keywords:solid electrolyte  electrochemical sensor  sulphur activity
本文献已被 CNKI 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号