摘    要:中盐株洲化工集团公司动力厂反渗透装置的膜受到活性炭和有机物污染后,产水量急剧下降。通过认真分析和试验,查明了原因,采取了应对措施,保证了系统正常运行。

关 键 词:活性炭  反渗透膜  有机物污染

Discussion on the Operation of Reverse Osmosis Contaminated by Active Carbon and Organism
Tan Feixiong. Discussion on the Operation of Reverse Osmosis Contaminated by Active Carbon and Organism[J]. sichuan chemical industry, 2009, 12(4): 47-49
Authors:Tan Feixiong
Affiliation:Power-supply department of ZhuZhou chemical industry group Co.Ltd;Zhuzhou;Hunan;412004
Abstract:The membrane in the RO device of power-supply department of ZhuZhou chemical industry group co.Ltd.was contaminated by active carbon and organism.it made output of deionized water suddenly drop.The author paid a great effort in analyzing and experimenting and finally found out the reason,Then a series of step was put into practice and the operation of RO system returned to normal.