首页 | 本学科首页   官方微博 | 高级检索  
     


On the Pulse Response of a Flush-Mounted Coaxial Aperture
Authors:Chang  DC Harrison  CW
Affiliation:Department of Electrical Engineering, University of Colorado, Boulder, Colo. 80302;
Abstract:The radiation field pattern of a flush-mounted coaxial aperture is derived in the frequency domain. By using the Lorentz reciprocity theorem, the equivalent current generator is obtained which drives the apparent annular antenna admittance in shunt with the load admittance. The current source, aperture admittance, and load admittance determine the transfer function. The transfer function multiplied by the expression for the spectrum of the incident pulse forms the integrand of the Fourier transform from which the time history of the current waveform in the load admittance may be obtained using a computer. There are several applications of the theory. The one of dominant interest at present may be described as follows. A coaxial transmission line terminated in a known load admittance is located in the interior of a missile. The free end of the cable forms an aperture antenna at the skin of the missile, i.e., at the normal junction of coaxial connectors. The problem is to determine the time history of the current in the load admittance when an intense transient electromagnetic field impinges on the receiving antenna. Very accurate numerical results may be obtained from this theory provided the ground plane is sufficiently large and certain dimensional limitations on the sizes of the inner conductor and sheath of the coaxial aperture (expressed in terms of the wavelength) are met.
Keywords: