首页 | 本学科首页   官方微博 | 高级检索  
     

三菱2290t/h锅炉再热器超温改造
引用本文:张洪刚,朱军. 三菱2290t/h锅炉再热器超温改造[J]. 广东电力, 2002, 15(3): 51-52,75
作者姓名:张洪刚  朱军
作者单位:珠海发电厂,广东珠海,519050
摘    要:某些大型燃煤机组,包括进口机组,锅炉受热面不同程度地存在着设计偏差。针对珠海电厂2290t/h燃煤锅炉存在的再热器超温爆管问题,进行了分析研究,论述了具体的改造措施。改造后,越温问题得以解决。

关 键 词:2290t/h锅炉 再热器 超温 技术改造 日本三菱公司
文章编号:1007-290X(2002)03-0051-02

Improving on over temperature situation on reheater of Mitsubishi 2 290 t/h boiler
ZHANG Hong-gang,ZHU Jun. Improving on over temperature situation on reheater of Mitsubishi 2 290 t/h boiler[J]. Guangdong Electric Power, 2002, 15(3): 51-52,75
Authors:ZHANG Hong-gang  ZHU Jun
Abstract:Some design deviations are discovered on boiler heaters of enormous coal-fired units, including imported units. The author analyses the over temperature problems on reheater tubes of a Mitsubishi 2 290 t/h coal-fired boiler in Zhuhai Power Station, and measures improved on the situation are described in this paper. After the improvement, the over temperature problem has been solved.
Keywords:Mitsubishi  boiler  reheater  over temperature  improvement
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号