Research on performance of regenerative room temperature magnetic refrigeration cycle |
| |
Authors: | Yu Bingfeng Zhang Yan Gao Qiang Yang Dexi |
| |
Affiliation: | aSchool of Energy and Power Engineering, Xi'an Jiaotong University, 28 Xianning West Road, Xi'an 710049, China |
| |
Abstract: | On the basis of classical Langevin theory along with statistical mechanics, thermodynamics and magnetism, a new expression of magnetocaloric parameters used for room temperature magnetic refrigeration is proposed, which is briefer and more accurate than the existing one, providing a new way for studying performance of regenerative room temperature magnetic Ericsson refrigeration cycle. Influences of temperature of heat reservoirs and magnetic intensity on cycle refrigeration capacity and coefficient of performance are analyzed. The results show that the maximal temperature span of the cycle increases but its increasing rate decreases with the increase of magnetic field strength. In addition, there exists only one maximum value of effective refrigerating capacity. Two cycles with the same COP can reach a same temperature span under a certain magnetic field strength. A large magnetic field strength can improve COP but the increase rate of COP decreases. |
| |
Keywords: | Research Magnetic refrigerator Process Calculation Performance COP Mots clés: Recherche Réfrigérateur magnétique Procédé Calcul Performance COP |
本文献已被 ScienceDirect 等数据库收录! |