摘    要:通过对山西平朔煤矸石电厂二期循环流化床机组锅炉主保护的调试,分析了循环流化床锅炉在保护设置和保护对象上的特点,主保护分为送风跳闸、锅炉跳闸、主燃料跳闸三部分。并分析了与常规煤粉炉存在的差异,对300MW循环流化床锅炉的实际运行具有一定的借鉴意义。

关 键 词:循环流化床  锅炉主保护  差异

Analysis of 300 MW Circulating Fluidized Bed Boiler Main Protection
WEN Wu,ZHOU Ce. Analysis of 300 MW Circulating Fluidized Bed Boiler Main Protection[J]. Shanxi Electric Power, 2009, 0(5): 38-40
Authors:WEN Wu  ZHOU Ce
Affiliation:(Shanxi Electric Power Research Institute, Taiyuan, Shanxi 030001, China)
Abstract:According to the debugging of circulating fluidized bed boiler main protection in the second phase of Shanxi Pingshuo Gangue Power Plant, the characters of circulating fluidized bed boiler on its protection set and protection object (include AT, BT, MFT) and the difference between circulating fluidized bed boiler and coal boiler are analyzed, which provides reference to the practical operation of 300 MW circulating fluidized bed boiler.