Experimental measurement of gas concentration distribution in an impinging entrained-flow gasifier |
| |
Authors: | Miaoren Niu Zhuoyong YanQinghua Guo Qinfeng LiangGuangsuo Yu Fuchen WangZunhong Yu |
| |
Affiliation: | Institute of Clean Coal Technology, East China University of Science and Technology, Mei Long Road No. 130, Shanghai, 200237, PR China; Key Laboratory of Coal Gasification of Ministry of Education, East China University of Science and Technology, Shanghai 200237, China |
| |
Abstract: | On a laboratory-scale testing platform of impinging entrained-flow gasifier with two opposed burners, the detailed measurements of gas concentration distribution have been performed for carbonaceous compound (diesel oil) at atmospheric pressure. Under the condition of 1.48–2.36 O/C ratios (kg/kg), radial gas samples are collected at three axial positions and the syngas exit position with stainless steel water-cooled probes, the concentration distribution of the major gases (H2, CO, CO2, CH4 and O2) under stable operating state was determined with a mass spectrometry. These data are used to clarify mixing and reaction characteristics within the reactor, to give insight into the combustion process and provide a database for evaluating predictive mathematical models. |
| |
Keywords: | Gasification Entrained-flow gasifier Gas concentration distribution |