摘    要:文章分析了Smart700IE触摸屏、S7-200PLC、MM440变频器组成的可视化小型系统功能的多样性和硬件的高性价比,通过通讯连接设置、变频器的参数设置、基本编程和组态,实现多种基本控制功能,说明该小型系统快速应用到现场的方法,为初次接触这种系统的工程人员提供一种范例。

关 键 词:触摸屏  PLC  通讯  调试

Connection and Application of Touch Screen With S7-200 and Frequency Converter
YAN Zhi-guo,LIU Qiang.Connection and Application of Touch Screen With S7-200 and Frequency Converter[J].Science & Technology of Baotou Steel(Group) Corporation,2017,43(2).
Authors:YAN Zhi-guo  LIU Qiang
Abstract:In this paper, it analyzes the functional diversity of the visualization mini type system composed of Smart700IE touch screen, S7-200PLC and MM440 inverter, and the high cost performance of the hardware, by setting up of the communication connect,inverter parameters, basic programming and configuration to realize a variety of basic control function, and explain the quick application methods of this mini type system, supplying an example for the engineers who first use this system.
Keywords:touch screen  PLC  communication  debugging