首页 | 本学科首页   官方微博 | 高级检索  
     


Survey of total and respirable suspended particulate matter in an iron foundry. Comparison of stationary sampling and personal monitoring
Authors:Jiqiang Zhang  Jeannine Billiet  Marcel Nagels  Richard Dams
Affiliation:Institute for Nuclear Sciences, Rijksuniversiteit Gent, Proeftuinstraat 86, B-9000 Gent Belgium
Abstract:In the workshop of an iron foundry total and respirable suspended particulate matter was collected. The performances of (1) filtration systems with 47 mm membrane filters, (2) Andersen cascade impactors, and (3) personal total or respirable monitoring, were compared at a position away from intense sources of particulate debris.Using 15 stationary samplers a survey was made of the particulate levels in the workshop, over a period of 2 weeks. Very large concentration gradients and concentration variations as a function of time were measured for total suspended particulate matter.In the three major source areas, i.e. the pouring department, the core-making department and the shake-out department, special studies were performed to compare stationary and personal monitoring.In the immediate vicinity of intense point sources of coarse particles, such as core-making or shake-out, stationary sampling cannot be used to estimate the personal exposure to total suspended particulates. For respirable particles, however, one or two well-situated stationary size-selective samplers can provide a good estimate of the personal exposure as measured with a personal respirable monitor. The differences found are in the order of 10–20%.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号