首页 | 本学科首页   官方微博 | 高级检索  
     


Gamma radiation nose system based on In/sub 2/O/sub 3//SiO thick-film sensors
Authors:Arshak   K.I. Korostynska   O.
Affiliation:Electron. & Comput. Eng. Dept., Univ. of Limerick, Ireland;
Abstract:A prototype gamma radiation monitoring system based on In/sub 2/O/sub 3//SiO thick-film sensors array was designed. Four sensors had an identical pn-heterojunction structure with different material compositions. These sensors were subjected to gamma radiation emitted by /sup 137/Cs source with an activity of 370 kBq. Changes in their current-voltage characteristics were recorded and compared. The performance parameters of the devices, such as sensitivity to /spl gamma/ radiation exposure and working dose region, were found to be highly dependent on the composition of the materials used. To cover a wider range of radiation and improve the overall sensitivity, an approach of using sensor arrays was utilized. A dynamic selection of the multiple sensors of various sensitivities and working dose ranges was implemented by applying a pattern recognition analysis.
Keywords: