首页 | 本学科首页   官方微博 | 高级检索  
     


The Development Of An Ozone Contact Tank Simulation Model
Authors:John Murrer  Jane Gunstead  Simon Lo
Affiliation:1. Anglian Water Services Ltd., Compass House, Chivers Way , Histon , Cambs , CB4 4ZY , UNITED KINGDOM;2. AEA Industrial Technology, B8, Harwell Laboratory , Oxfordshire , 0X11 0RA , UNITED KINGDOM
Abstract:Anglian Water (AW) operates ozone facilities as a treatment stage at all its surface water sources. The main ozone treatment stage takes place after filtration in multi-compartment concrete ozone contactors. These have two stages of ozone gas injection via ceramic bubble diffusers and two decay stages.

To enable AW to gain a better understanding of the contact tank performance, a computer simulation model incorporating Computational Fluid Dynamics and ozone process modeling was developed in conjunction with AEA Harwell. The model was calibrated using site data from Alton WTW. The results were used to improve the tank design and to optimize the ozone dose; this resulted in improved performance and a significant reduction in ozone dose.

Keywords:Ozone  Ozone Contacting  Modeling of Ozone Contactor  Disinfection  Computational Fluid Dynamics  Alton (UK) Water Treatment Plant
设为首页 | 免责声明 | 关于勤云 | 加入收藏