首页 | 本学科首页   官方微博 | 高级检索  
     


Working fluids for an absorption system based on R124 (2-chloro-1,1,1,2,-tetrafluoroethane) and organic absorbents
Authors:I Borde  M Jelinek  N.C Daltrophe
Affiliation:Mechanical Engineering Department, Ben-Gurion University of the Negev, P.O. Box 653, Beer-Sheva 84105, Israel;The Institutes for Applied Research, Ben-Gurion University of the Negev, P.O. Box 653, Beer-Sheva 84105, Israel
Abstract:The possibility of using R124 (2-chloro-1,1,1,2,-tetrafluoroethane, CHClFCF3) and organic absorbents as working fluids in absorption heat pumps was investigated. Various classes of organic compounds, all commercially available, were tested as absorbents for possible combination with R124; the absorbents included DMAC (N′, N′-dimethylacetamide, C4H9NO), NMP (N-methyl-2-pyrrolidone, C5H9NO), MCL (N-methyl ε-caprolactam, C7H13NO), DMEU (dimethylethylene urea, C5H10N2O), and DMETEG (dimethylether tetraethyleneglycol, C10H22O5). To evaluate the performance of a candidate refrigerant-absorbent pair in a refrigeration or heat pump cycle, the thermophysical properties of the pure components and the mixture and the equilibrium and transport properties have to be determined, either from experimental data or by prediction methods. The thermal stability of the refrigerant-absorbent must also be tested. A method for the calculation of the concentration in the liquid and gas phases and the excess thermodynamic properties of the mixture as a function of the system temperature and pressure based on our experimental setup is described. On the basis of vapor-liquid equilibrium measurements, density and viscosity measurements and thermostability testing, enthalpy-concentration diagrams were constructed. The performance characteristics of the investigated working fluids in terms of the coefficient of performance (COP) and the circulation ratio (f) were calculated for a single-stage absorption cycle. In terms of overall performance (COP, f and stability) R124-DMAC was found to be the superior combination, followed by R124-NMP, R124-DMEU and R124-MCL (the three pairs for which stability problems were found at high temperatures), and finally by R124-DMETEG.
Keywords:absorption machine   absorbant   chemical composition   thermo-dynamic property   measurement   COPmachine à   absorption   R124   absorbant   composition chimique   proprié     thermodynamique   mesure   COP
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号