首页 | 本学科首页   官方微博 | 高级检索  
     

燃煤电站锅炉一次风机电流大原因分析
引用本文:邢希东.燃煤电站锅炉一次风机电流大原因分析[J].风机技术,2011(2):62-66.
作者姓名:邢希东
作者单位:天津大唐国际盘山发电有限责任公司
摘    要:通过对风烟系统、一次风机、变频器以及空预器等设备系统进行各种对比试验分析,结合机组检修,证明了空预器密封装置严重磨损导致漏风率突增是一次风机单耗不正常升高的原因,并提出了合理建议.

关 键 词:节能降耗  变频器  空预器  漏风率

Analysis of the Reason of Big Current in Primary Coal-fired Boiler Fan
Xing Xidong.Analysis of the Reason of Big Current in Primary Coal-fired Boiler Fan[J].Compressor Blower & Fan Technology,2011(2):62-66.
Authors:Xing Xidong
Abstract:Through a variety of comparison and test analysis for the equipment system of wind and smoke system,primary fan,inverter and air preheater,it is proved combining units maintenance that the air leakage rate suddenly increased due to the serious wear of air preheater seal device is the real reason of causing the consumption of primary fan abnormally increased.So the reasonable advice is pointed out.
Keywords:energy saving and consumption reduction  inverter  air preheater  air leakage rate  