摘    要:Catalytic wet air oxidation (CWAO) was investigated in laboratory-scale experiments for the treatment of o-chlorophenol in wastewater. Experimental results showed that wet air oxidation (WAO) process in the absence of catalyst was also effective for o-chlorophenol in wastewater treatment. Up to 80% of the initial CODCr was removed by wet air oxidation at 270℃ with twice amount of the required stoichiometric oxygen supply. At temperature of 150℃, the removal rate of CODCr was only 30%. Fe2(SO4)3, CuSO4, Cu(NO3)2 and MnSO4 exhibited high catalytic activity. Higher removal rate of CODCr was obtained by CWAO. More than 96% of the initial CODCr was removed at 270℃ and 84.6%-93.6% of the initial CODCr was removed at 150℃. Mixed catalysts had better catalytic activity for the degradation of o-chlorophenol in wastewater.

关 键 词:接触反应 催化湿式氧化处理 邻氯苯酚 废水处理 催化剂
修稿时间: 

Catalytic Wet Air Oxidation of o-Chlorophenol in Wastewater
XU Xinhua,WANG Dahui. Catalytic Wet Air Oxidation of o-Chlorophenol in Wastewater[J]. Chinese Journal of Chemical Engineering, 2003, 11(3): 352-354
Authors:XU Xinhua  WANG Dahui
Affiliation:Department of Environmental Engineering, Zhejiang University, Hangzhou 310027, China
Abstract:Catalytic wet air oxidation (CWAO) was investigated in laboratory-scale experiments for the
Keywords:o-chlorophenol wastewater  wet air oxidation  catalyst
本文献已被 维普 万方数据 等数据库收录!
点击此处可从《中国化学工程学报》浏览原始摘要信息
点击此处可从《中国化学工程学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号