首页 | 本学科首页   官方微博 | 高级检索  
     


Fire behavior of eccentrically loaded slender high strength concrete-filled tubular columns
Affiliation:1. Centro Técnico del Fuego (CTF), AIDICO, Valencia, Spain;2. Instituto de Ciencia y Tecnología del Hormigón (ICITECH), Universitat Politècnica de València, Spain;1. School of Civil and Transportation Engineering, Guangdong University of Technology, 100 Waihuan Xi Road, GuangZhou 510006, China;2. Department of Civil and Environmental Engineering, National University of Singapore, 1 Engineering Drive 2, Singapore 117576, Singapore;3. School of Civil Engineering, Nanjing Tech University, NO. 30 Puzhu Road(S), Nanjing 211816, China;1. Instituto de Ciencia y Tecnología del Hormigón (ICITECH), Universitat Politècnica de València, Valencia, Spain;2. Department of Mechanical Engineering and Construction, Universitat Jaume I, Castellón, Spain
Abstract:This paper describes a series of 24 fire tests conducted on slender circular hollow section columns filled with normal and high strength concrete, subjected to eccentric axial load. It is a continuation of a previous research paper (Romero et al., 2011 1]), where test results on centrally loaded columns were presented. The test parameters covered in this fire testing program were the nominal strength of concrete (30 and 90 MPa), the infilling type (plain, bar-reinforced and steel fiber reinforced concrete), the axial load level (20% and 40%) and the load eccentricity (20 and 50 mm). The columns were tested under fixed-pinned boundary conditions, with a relative slenderness at room temperature higher than 0.5 for all the specimens. The aim of this paper is to study the influence of eccentricity in combination with the type of concrete infill. The results show that the addition of steel fibers does not improve the fire resistance of slender columns under eccentric loads, as compared to columns filled with plain concrete. However, the addition of reinforcing bars increases the fire resistance of the columns in this situation. Filling the steel hollow section columns with concrete increases their fire resistance, the increase in load bearing capacity being more noticeable for columns filled with high strength concrete. A comparison with the current simple calculation model in Eurocode 4 Part 1.2 shows that, although the method is safe for eccentrically loaded columns, it produces a high error in the predictions for columns filled with plain or steel fiber reinforced concrete.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号