Numerical and experimental investigations on effect of fan height on the performance of piezoelectric fan in microelectronic cooling
Authors:M.K. Abdullah  M.Z. AbdullahM.V. Ramana  C.Y. KhorK.A. Ahmad  M.A. MujeebuY. Ooi  Z. Mohd Ripin
Affiliation:Aerodynamic and Advanced Cooling Laboratory, School of Mechanical and Aerospace Engineering, Engineering Campus, Universiti Sains Malaysia, 14300 Nibong Tebal, Penang, Malaysia
Abstract:A piezoelectric fan is an attractive device to remove heat from microelectronic systems due to its low power consumption, minimal noise and compactness. In the present study, a piezoelectric fan is investigated to analyze the cooling capability for possible use in electronic devices. Both numerical and experimental analyses are carried out on the piezoelectric fan which was oriented horizontally. The FLUENT 6.3 software is used in the 2D simulation to predict the heat transfer coefficient and the flow fields using a dynamic mesh option to observe the fan swinging phenomena. Two heat sources in in-line arrangement are used in the experiment. The flow measurements are carried out at different piezoelectric fan heights by using a particle image velocimetry (PIV) system. The result shows that the piezofan height of hp/lp = 0.23 can reduce the temperature of the heat source surface as much as 68.9 °C. The numerical and experimental values of heat transfer coefficients are plotted and found in good agreement.
Keywords:Microelectronic cooling   Piezoelectric fan   Heat transfer coefficient   Particle image velocimetry