A new HPF specimen carrier adapter for the use of high‐pressure freezing with cryoscanning electron microscope: two applications: stearic acid organization in a hydroxypropyl methylcellulose matrix and mice myocardium
Authors:B. PAYRE  E. GONTIER  A. JARRAY  Y. MARTINEZ  J.P. LAUGIER  A. DELALLEAU  B.M. GAILLARD  I. ANSELME  D. GOUDOUNÈCHE  I. FOURQUAUX  M. HEMATI  V. GERBAUD  M.B. DELISLE  C. GUILBEAU‐FRUGIER
Affiliation:1. Centre de Microscopie Electronique Appliquée à la Biologie, Faculté de Médecine Rangueil, Toulouse III, P. Sabatier University, Toulouse, France;2. Bordeaux Imaging Center ‐ UMS 3420‐Université Bordeaux / CNRS / INSERM, Bordeaux, France;3. LGC, INP, ENSIACET, 4 Allée Emile Monso, Toulouse, France;4. CNRS, FR3450, Federation de recherche Agrobiosciences, Interactions, Biodiversité, Castanet Tolosan, France;5. Centre Commun de Microscopie Appliquée, Université de Nice‐Sophia Antipolis, Nice, France;6. Pixience, 12 rue Louis Courtois de Vi?ose, Toulouse, France;7. INRA, Centre Clermont‐Ferrand ‐ Theix, UMR1019, University of Clermont‐Ferrand 1, Clermont‐Ferrand, France;8. Centre de Microscopie Electronique Stéphanois ‐ CMES‐Saint Etienne, Université de Lyon, Saint‐Etienne, France;9. CHU Toulouse and INSERM U 1037, Toulouse CEDEX, France
Abstract:Cryogenic transmission electron microscopy of high‐pressure freezing (HPF) samples is a well‐established technique for the analysis of liquid containing specimens. This technique enables observation without removing water or other volatile components. The HPF technique is less used in scanning electron microscopy (SEM) due to the lack of a suitable HPF specimen carrier adapter. The traditional SEM cryotransfer system (PP3000T Quorum Laughton, East Sussex, UK; Alto Gatan, Pleasanton, CA, USA) usually uses nitrogen slush. Unfortunately, and unlike HPF, nitrogen slush produces water crystal artefacts. So, we propose a new HPF specimen carrier adapter for sample transfer from HPF system to cryogenic‐scanning electronic microscope (Cryo‐SEM). The new transfer system is validated using technical two applications, a stearic acid in hydroxypropyl methylcellulose solution and mice myocardium. Preservation of samples is suitable in both cases. Cryo‐SEM examination of HPF samples enables a good correlation between acid stearic liquid concentration and acid stearic occupation surface (only for homogeneous solution). For biological samples as myocardium, cytoplasmic structures of cardiomyocyte are easily recognized with adequate preservation of organelle contacts and inner cell organization. We expect this new HPF specimen carrier adapter would enable more SEM‐studies using HPF.
Keywords:Cryogenic scanning electron microscopy  Cryogenic fracture  Cryogenic freezing  High‐pressure freezing  HPF specimen carrier adapter