首页 | 本学科首页   官方微博 | 高级检索  
     


Development of a flow meter for instantaneous flow rate measurements of anaesthetic liquids
Authors:F Durst  A Melling  D Trimis  P Volkholz
Affiliation:

Lehrstuhl für Strömungsmechanik, Universität Erlangen-Nürnberg, Cauerstr. 4, D-91058, Erlangen, Germany

Abstract:An instrument has been developed for instantaneous flow rate measurements of anaesthetic liquids. For periodically time-varying flows, the instantaneous flow rate is reconstructed from the axial velocity time series measured on the centre-line of a pipe. The theoretical background for the method is given and it is demonstrated that fast variations of flow rate can be measured. The instrument is based on a laser Doppler anemometer (LDA) to record the instantaneous velocity on the axis of a capillary; an ultraviolet laser permits velocity measurements with good signal-to-noise ratio from tracer particles in the submicrometer range present in anaesthetic liquids.
Keywords:instantaneous flow rate  anaesthetic liquids  laser Doppler anemometry
本文献已被 ScienceDirect 等数据库收录!