首页 | 本学科首页   官方微博 | 高级检索  
     

微波诱发工作人员外周血淋巴细胞亚群变化情况调查
引用本文:尹金玲,满其航,崔玉芳,杜丽. 微波诱发工作人员外周血淋巴细胞亚群变化情况调查[J]. 辐射防护通讯, 2011, 0(5): 14-17
作者姓名:尹金玲  满其航  崔玉芳  杜丽
作者单位:航天中心医院职业病科;军事医学科学院放射与辐射医学研究所
基金项目:国家自然科学基金(39000386);毫米波国家重点实验室开放课题(K200909);军队医药卫生“十一五”基金(09MA026)
摘    要:对某研究所微波接触人员(接触组)和非微波作业人员(对照组)进行调查,调查指标为外周血白细胞数和淋巴细胞百分率,以及T淋巴细胞亚群CD3+、CD4+、CD8+比例和CD4+/CD8+比值,探索长期低剂量高功率微波辐射对工作人员免疫功能的影响。结果表明:与对照组相比,接触组白细胞数和淋巴细胞百分比均降低,但差异不显著;接触组CD3+、CD4+、CD8+比例均升高,CD4+/CD8+比值降低,差异显著;接触组≤10a组的T细胞亚群的变化差异不显著,接触组〉10a组CD3+、CD4+、CD8+比例及CD4+/CD8+比值均升高,且CD3+比例升高差异显著;接触组和对照组组内工龄≤10a和)10a间T淋巴细胞亚群的差异不显著。结果提示,低剂量高功率微波辐射能明显导致人体免疫功能紊乱,但未表现出累积效应。客观有效的职业防护应当引起关注。

关 键 词:微波  淋巴细胞  T淋巴细胞亚群

Effects of Microwave Radiation on T Lymphocytes of Workers
Yin Jinling Man QihangAerospace Center Hospital,Beijing,Cui Yufang Du Li. Effects of Microwave Radiation on T Lymphocytes of Workers[J]. Radiation Protection Bulletin, 2011, 0(5): 14-17
Authors:Yin Jinling Man QihangAerospace Center Hospital  Beijing  Cui Yufang Du Li
Affiliation:(Beijing Institute of Radiation Medicing,Beijing,100850)
Abstract:To investigate the effects of long-term, low-dose and high-power microwave radiation on immuno-logic function of workers. The changes of peripheral blood leukocytes, lymphocyte percentage, and CD3+ , CD4+ , CD8+ T cells and ratios of CD4+/CD8+ were determined in 38 microwave radiation-exposed workers (exposed group) and 39 non-microwave radiation-exposed workers (control group). Compared with the control group, peripheral blood leukocytes and lymphocyte percentage were decreased in the exposed group, but the difference was not significant. CD3+, CD4+ , CD8+ cells were increased significantly and ratio of CD4+/ CD8+ was diminished significantly in the exposed group. In the exposed group, T cell subsets in ≤ 10 years service length group was not significant as compared with the control group. But CD3+, CD4+ , CD8+ cells and ratio of CD4+/CD8+ were increased in 〉 10 years service length group of the exposed group, and CD3+ cells were increased significantly. Inaddition, 2 service length groups within the exposed group and control group, CD3+, CD4+ , CD8+ T ceils and ratio of CD4+/CD8+ were not significant. The Long-term, low-dosage and high-power microwave radiation can cause significant immune dysfunction to the exposed workers, but without cumulative effects. Effective occupational protection should be adopted.
Keywords:Microwave Lymphocyte T cell subsets
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号