摘    要:目的 比较PCR法、胶体金法和VITEK-2 Compact法检测沙门氏菌的检测效果。方法 使用PCR法、胶体金法和VITEK-2 Compact法和国标法分别对待测样品进行检测, 并将3种快速检测方法的检测结果与国标法检测结果进行对比分析。结果 3种快速检测法的检测结果和国标法检测结果符合率分别为100%、92.9%和100%, PCR法和VITEK-2 Compact法符合率略高于胶体金法, 但3种快速检测方法总检出率与国标法比较差异均无统计学意义(P>0.05), PCR法、胶体金法和VITEK-2 Compact法对35个沙门氏菌阳性样本的检出率分别为100%、85.7%和100%。针对阳性样品, PCR法和VITEK-2 Compact法高于胶体金法, 且差异有统计学意义(P<0.05)。PCR法和VITEK-2 Compact法对沙门氏菌的最低检出限为1×101 CFU/mL, 而胶体金法为1×102 CFU/mL。结论 3种快速检测方法均可作为沙门氏菌国标检测方法的有效补充。

关 键 词:沙门氏菌   快速检测   胶体金   PCR   VITEK-2 Compact
收稿时间:2019-05-15
修稿时间:2019-06-09

Comparative analysis of 3 rapid detection methods for Salmonella
CAI Biao,DAI Chen-Wei,LV Han,DIAO Hui-Min,JIANG Yang-Fan and XIN Ji-Di. Comparative analysis of 3 rapid detection methods for Salmonella[J]. Journal of Food Safety & Quality, 2019, 10(18): 6036-6041
Authors:CAI Biao  DAI Chen-Wei  LV Han  DIAO Hui-Min  JIANG Yang-Fan  XIN Ji-Di
Affiliation:The Medical Science Institute of Anhui Province,The Medical Science Institute of Anhui Province,The Medical Science Institute of Anhui Province,The Medical Science Institute of Anhui Province,The Medical Science Institute of Anhui Province and The Medical Science Institute of Anhui Province
Abstract:Objective To compare the detection results of Salmonella by the method of PCR, colloidal gold and VITEK-2 Compact, respectively. Methods The samples were tested by the method of PCR, colloidal gold and VITEK-2 Compact and national standard, and the detection results of the former 3 kinds of rapid detection methods were compared with the national standard method. Results Compared with the national standard method, the coincidence rates of PCR, colloidal gold and VITEK-2 Compact were 100%, 92.9%, and 100%%, respectively. The PCR and VETIK method had the same coincidence rate, and slightly higer than the colloidal gold method, but there was no significant difference between the detection rates of the 3 rapid detection methods and the national standard method (P>0.05). The detection rates of 35 Salmonella positive samples by PCR, colloidal gold and VITEK-2 Compact were 100%, 85.7% and 100%, respectively. The PCR method and VITEK-2 Compact method were higher than the colloidal gold method for the positive sample, and the difference was statistical significance (P<0.05). The minimum detection limit for Salmonella by PCR and VITEK-2 Compact was 1×101 CFU/mL, while the colloidal gold method was 1×102 CFU/mL. Conclusion All the 3 rapid detection methods can be used as an effective supplement to the Salmonella national standard.
Keywords:Salmonella spp.   rapid detection   colloidal gold   PCR   VITEK-2 Compact
点击此处可从《食品安全质量检测学报》浏览原始摘要信息
点击此处可从《食品安全质量检测学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号