首页 | 本学科首页   官方微博 | 高级检索  
     

GFM铅蓄电池的运行维护
引用本文:王超,卫功存,张霁月.GFM铅蓄电池的运行维护[J].电池工业,2014(2):87-90.
作者姓名:王超  卫功存  张霁月
作者单位:六安供电公司,安徽六安237006
摘    要:GFM(固定型阀控式密封)铅蓄电池是直流系统不间断供电的重要设备。然而,如果对蓄电池运行维护不到位,就会引起电池提前老化,造成容量损失,缩短寿命,影响整个电力系统安全。通过处理六安某县公司110kV变电站一起蓄电池故障,结合工作实际分析总结出蓄电池运行维护要点,从而提高整个直流系统安全可靠性。

关 键 词:电力系统  铅蓄电池  运行维护  安全运行

Operation and maintenance of GFM lead-acid battery
WANG Chao,WEI Gong-cun,ZHANG Ji-yue.Operation and maintenance of GFM lead-acid battery[J].Chinese Battery Industry,2014(2):87-90.
Authors:WANG Chao  WEI Gong-cun  ZHANG Ji-yue
Affiliation:(Luan Power Supply Company, Luan ,Anhui 237006,China)
Abstract:GFM (fixed type valve-requlated sealed)lead-acid batteries are important devices of un-interruptible power supplies for DC system.However,if the battery operation is not in place,it can cause premature aging batteries,caused volume loss,shortened life expectancy,and affects the entire power system security.Through a county in luan company 110kV substation battery failure,combined with the actual analysis summary the battery operation and maintenance,thus improving the whole DC system's safety and reliability.
Keywords:power systems  lead-acid batteries  maintenance  safe operation