摘    要:高压断路器液压机构故障会威胁电网安全可靠运行。本文针对经常发生在东观变电站的LW6-220hW型断路器液压机构故障,进行了分析,提出了从根本上处理液压机构故障的建议。

关 键 词:高压断路器  液压机构  微动开关

Analysis and Settlement of Hydraulic Mechanistic Breakdowns of HV Circuit Breakers
Wang Jianwei,Zhang Lijin.Analysis and Settlement of Hydraulic Mechanistic Breakdowns of HV Circuit Breakers[J].Journal of Electric Power,1997,12(4):68-72.
Authors:Wang Jianwei  Zhang Lijin
Affiliation:Jin Zhong Company of Power Supply YuCi Shanxi Province
Abstract:Hydraulic mechanistic breakdowns of HV circuit breakers can threaten the safty of the power network seriously. Based on the case of the DongGuan transformation station,the paper sums up the Hydraulic mechanism of LW6-220HW Circuit breakers main characters,analyses the reasons which break downs had occured,and gives the proposal of settlement.
Keywords:HV circuit breakers  Hydraulic mechanism  Micro adjustment switch