首页 | 本学科首页   官方微博 | 高级检索  
     

紧水滩大坝2#中孔泄槽混凝土缺陷检查及灌浆处理
引用本文:张巍. 紧水滩大坝2#中孔泄槽混凝土缺陷检查及灌浆处理[J]. 大坝与安全, 2002, 0(4): 41-43
作者姓名:张巍
作者单位:紧水滩水力发电厂,浙江,云和,323603
摘    要:紧水滩大坝2#中孔泄槽左侧墙与电站主厂房右端墙紧贴,中孔泄洪时因泄槽混凝土存在缺陷而导致厂房进水,严重威胁机组的安全运行,经反复检查终于发现泄槽底板混凝土存在大范围的浇筑缺陷,采用孔口封闭纯压式回填灌浆进行工程处理取得了消缺成功。

关 键 词:紧水滩大坝  中孔  泄槽  缺陷  检查  灌浆
文章编号:1671-1092(2002)04-0041-03
修稿时间:2001-11-28

Defect check to concrete of discharge chute of central outlet No.2 in Jinshuitan Dam and grouting treatment
by Zhang Wei//Jinshuitan Hydropower Plant. Defect check to concrete of discharge chute of central outlet No.2 in Jinshuitan Dam and grouting treatment[J]. Large Dam & Safety, 2002, 0(4): 41-43
Authors:by Zhang Wei//Jinshuitan Hydropower Plant
Affiliation:by Zhang Wei//Jinshuitan Hydropower Plant
Abstract:Left curb wall of the central discharging chute No.2in Jinshuitan Dam is tightly close to the right wall of main powerhouse,powerhouse are inundated at central discharging because of defective concrete in chute,which seriously endanger the safety operation of the units.It was found that a wide range concrete casting defects were located in chute bottom by checks,so it is suggested that orifice closed backfill grouting on pressure only should be conducted.
Keywords:Jinshuitan Dam  central outlet  discharge chute  defects  check  grouting
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏