摘    要:根据短肢剪力墙的受力特点,导出了短肢剪力墙中连梁高跨比应满足的条件,从而给出短肢剪力墙的判别依据,以供工程设计参考。另外,还对某些文献中的一些观点提出了不同看法。

关 键 词:短肢剪力墙  连梁  高跨比  力学性能  判别依据

ANALYSIS OF MECHANICAL PROPERTY OF SHORT-PIER SHEAR WALL
Hu Shulan.ANALYSIS OF MECHANICAL PROPERTY OF SHORT-PIER SHEAR WALL[J].Industrial Construction,2008,38(9).
Authors:Hu Shulan
Abstract:According to the mechanical characteristics of short-pier shear wall, the conditions meeting the ratio of connecting beam height to its span in short-pier shear wall have been derived.From this,the defining criterion of short-pier shear wall may be presented,which may be referred to engineering design.In addition,any viewpoint different from some papers has been advanced.