工厂110kV变电站电能损耗分析及节能措施
引用本文:姚继强. 工厂110kV变电站电能损耗分析及节能措施[J]. 铜业工程, 2014, 0(3): 71-74
作者姓名:姚继强
作者单位:江西铜业集团公司贵溪冶炼厂,江西贵溪335424
摘    要:针对贵冶1#总降压110kV变电站电能损耗现状,结合贵冶一系统供配电特点,认真分析了功率因数、电抗器与电能损耗之间的关系,提出了降低变电站电能损耗的应对措施--提高功率因数和取消电抗器,最后总结了变电站节能降耗的现实意义。

关 键 词:电能损耗  供配电  功率因数  电抗器  应对措施  节能降耗

Analysis on Electric Energy Loss and Measures of Guixi Smelter 110kV Transformer Substation
Affiliation:YAO Ji - qiang (Guixi Smelter of Jiangxi Copper Corporation, Guixi 335424, Jiangxi, China)
Abstract:Aiming at the current situation of Guixi Smelter 110kV transformer substation electric energy loss,combined with the first system characteristics of power supply and distribution,the relations between power factor,Electric reactor and electric energy loss are analyzed carefully,the measures to reduce electric energy loss of transformer substation of improve the power factor and cancel reactor are proposed,and finally the significance of energy saving for transformer substation is summarized in this article.
Keywords:electric energy loss  power supply and distribution  power facto  reactor  measures  energy saving