Construction of new iodide selective electrodes based on bis(trans-cinnamaldehyde)1,3-propanediimine(L) zinc(II) chloride [ZnLCl2] and bis(trans-cinnamaldehyde) 1,3-propanediimine(L) cadmium(II) chloride [CdLCl2] |
| |
Authors: | M. Ghaedi M. MontazerozohoriA. Mousavi S. KhodadoustM. Mansouri |
| |
Affiliation: | Department of Chemistry, University of Yasouj, Yasouj 75914-353, Iran |
| |
Abstract: | New plasticized PVC membranes iodide selective electrodes have been prepared by incorporating bis(trans-cinnamaldehyde)1,3-propanediimine zinc(II) chloride [ZnLCl2] and bis(trans-cinnamaldehyde) 1,3-propandiimine cadmium(II) chloride [CdLCl2] on the surface of graphite disk electrodes. At optimum value of variables the proposed electrodes have selective response to iodide with respect to a number of inorganic and organic anions with near-Nernstian slopes of − 60 ± 1.9 and − 58.5 ± 1.9 mV/decade of iodide concentration over the range 1.0 × 10− 6-1.0 × 10− 1 M with detection limits of 4.0 × 10− 7 and 3.0 × 10− 7 M for the electrodes based on [ZnLCl2] and [CdLCl2], respectively. The electrodes based on both ionophores have response times of about (6 s), with stable reproducible response during 2 months, while their responses is independent of pH over the range 2.5-10.5. The proposed electrodes successfully have been applied for evaluation of iodide ion content in real samples with complicated matrices including water and pharmaceutical samples. |
| |
Keywords: | Iodide selective electrode Potentiometric sensors Coated-graphite electrode Bis(trans-cinnamaldehyde)1,3-propanediimine zinc(II) chloride [ZnLCl2] Bis(trans-cinnamaldehyde) 1,3-propanediimine cadmium(II) chloride [CdLCl2] |
本文献已被 ScienceDirect 等数据库收录! |
|