600MW超超临界发电机内冷水系统树脂泄漏分析与处理
引用本文:蔡萍.600MW超超临界发电机内冷水系统树脂泄漏分析与处理[J].江苏电机工程,2010,29(3):80-81.
作者姓名:蔡萍
作者单位:江苏阚山发电有限公司,江苏,徐州,221134
摘    要:发电机内冷水系统离子交换器在运行过程中发生树脂泄漏,并有少量的树脂漏入发电机定子线圈中。针对该问题,分析了泄漏的原因,并采用气、水共振法对发电机定子线圈进行冲洗,取得了较好的效果。

关 键 词:发电机内冷水  树脂泄漏  冲洗

Analysis and Treatment of Resin Leakage into the Generator Inner Cooling Water System of 600 MW Ultra-Supercritical Power Units
CAI Ping.Analysis and Treatment of Resin Leakage into the Generator Inner Cooling Water System of 600 MW Ultra-Supercritical Power Units[J].Jiangsu Electrical Engineering,2010,29(3):80-81.
Authors:CAI Ping
Affiliation:CAI Ping (Jiangsu Kanshan Power Generation Co. Ltd., Xuzhou 221134, China)
Abstract:Resin leakage takes place in the ion exchange of generator inner cooling water system during the operation process, and this condition has led to a little leakage of resin into the generator stator coil. In order to solve the problem, the reasons for the leakage are analyzed in the paper, and the gas-water resonance method is adopted to wash the generator stator coil. Good results have been achieved.
Keywords:generator inner cooling water  resin leakage  wash