首页 | 本学科首页   官方微博 | 高级检索  
     

核电站凝结水泵气蚀保护的改进
引用本文:罗传杰,漆向前,周琦. 核电站凝结水泵气蚀保护的改进[J]. 广东电力, 2011, 24(4): 31-33
作者姓名:罗传杰  漆向前  周琦
作者单位:中科华核电技术研究院;中广核工程有限公司;
摘    要:针对大亚湾核电站和岭澳核电站的常规岛凝结水系统凝结水泵因进、出口差压大和差压开关长期工作在高差压的环境下容易损坏,导致保护系统跳闸的问题,通过分析和计算,提出了将凝结水泵的气蚀保护由差压保护改为出口压力保护的改进方案,解决了差压开关容易发生故障的问题.改进实施后,效果良好,现场没有发生类似故障.

关 键 词:核电站  凝结水泵  差压开关  气蚀

Improvement on Cavitation Erosion Protection of Condensate Pump in Nuclear Power Station
LUO Chuan-jie,QI Xiang-qian,ZHOU Qi. Improvement on Cavitation Erosion Protection of Condensate Pump in Nuclear Power Station[J]. Guangdong Electric Power, 2011, 24(4): 31-33
Authors:LUO Chuan-jie  QI Xiang-qian  ZHOU Qi
Affiliation:LUO Chuan-jie1,QI Xiang-qian2,ZHOU Qi1(1.China Nuclear Power Research Institute,Shenzhen,Guangdong 518124,China,2.China Nuclear Power Engineering Company,China)
Abstract:Aiming at tripping of protection system caused by huge differential pressure between the inlet and outlet of condensate pump of condensate system in conventional islands of Dayawan nuclear power station and Lingao nuclear power station as well as vulnerability of differential pressure switch that works in high differential pressure environment for long,the paper proposes to substitute exit pressure protection for differential pressure protection,settling the problems that there are frequent faults in differ...
Keywords:nuclear power station  condensate pump  differential pressure switch  cavitation erosion  