摘    要:在对常规变电站进行无人值班的改造过程中,根据多年的运行考验,暴露出一些问题,针对重合闸回路提出新的改造方案,解决了重合闸不能可靠闭锁的问题。

关 键 词:无人值班变电站   重合闸回路   闭锁
文章编号:1003-4897(2005)20-0085-02
收稿时间:2005-02-24
修稿时间:2005-04-04

Analysis and development of reclosure circuit in 110 kV conventional unattended substation
LIU Ji-an, YANG Guo-ting. Analysis and development of reclosure circuit in 110 kV conventional unattended substation[J]. Power System Protection and Control, 2005, 33(20): 90-91
Authors:LIU Ji-an   YANG Guo-ting
Affiliation:1. Puyang Power Supply Bureau, Puyang 457000, China; 2. Shouguang Power Supply Company, Shouguang 262700, China
Abstract:Some problems is found out in reforming conventional unattended substation, according to years of operation test experience. To the reclosure circuit, several reforming schemes are put forward to solve the problem of reclosure unstable locking.