首页 | 本学科首页   官方微博 | 高级检索  
     

液固流化床分选粗煤泥的试验研究
引用本文:沙杰,谢广元,王宏,刘均章.液固流化床分选粗煤泥的试验研究[J].煤炭学报,2012,37(Z1):178-181.
作者姓名:沙杰  谢广元  王宏  刘均章
作者单位:中国矿业大学 化工学院,江苏 徐州 221116
基金项目:国家自然科学基金资助项目(50974120);中央高校基本科研业务费资助项目(2010QNB08)
摘    要:自制了直径300 mm液固流化床模型机分选试验系统,并分别设计了中心排料型和周边排料型流体分布器,分别对0.25~1.00 mm粗煤泥进行了3个不同柱体高度的分选试验。结果表明:随着水流速度的增加,精煤灰分、尾煤灰分、精煤可燃体回收率都随之升高;分选密度达到1.5 g/cm 3左右,可能偏差E值在0.06~0.08;在一定的上升水流范围内,高柱体的精煤灰分低于低柱体,1 800 mm柱体高度下得到的精煤灰分比1 200 mm的精煤灰分低0.6%~1.2%;1 500 mm柱体高度下的分选效果最佳,中心排料型流体分布器的E值较低,分选效果优于周边排料型流体分布器。

关 键 词:液固流化床  粗煤泥  柱体高度  中心排料  周边排料  
收稿时间:2011-11-28

Experimental study on coarse coal slime separation in a liquid-solid fluidized bed separator
SHA Jie,XIE Guang-yuan,WANG Hong,LIU Jun-zhang.Experimental study on coarse coal slime separation in a liquid-solid fluidized bed separator[J].Journal of China Coal Society,2012,37(Z1):178-181.
Authors:SHA Jie  XIE Guang-yuan  WANG Hong  LIU Jun-zhang
Affiliation:1.School of Chemical Engineering and Technology,China University of Mining and Technology,Xuzhou 221116,China;2.Beijing Huayu Engineering Co,.Ltd.,China Coal Technology & Engineering Group Corp.,Pingdingshan 467000,China)
Abstract:A liquid-solid fluidized bed model in 300 mm diameter was established,and two kinds of liquid distributors,a central discharge and a peripheral discharge,were designed into the hindered fluidized bed separator.The beneficiation performance of the fluidized bed was investigated using 0.25~1.00 mm coarse coal slime in three different heights of separator and in the two distributors.The experimental results show that the clean coal ash content,the tailings ash content,and the combustible material recovery all increase as the superficial water velocity increases.The probable error E ranging 0.06~0.08 was obtained at the separation density of about 1.5 g/cm3.At a certain superficial water velocity,the clean coal ash content decreases along with the increase of the height of the separator,and the clean coal ash content of 1 800 mm height is 0.6% to 1.2% lower than that of 1 200 mm height.The optimal separation effect of the height of the separator is 1 500 mm.Additionally,the probable error E of the central discharge is lower,and its separation effect is also better than that of the peripheral discharge.
Keywords:liquid-solid fluidized bed  coarse coal slime  column height  central discharge  peripheral discharge
本文献已被 CNKI 等数据库收录!